How much will a higher SEER2 save?

Put in your old system, your state and the new rating. You get the kWh and dollars a year, the payback, and DOE's minimum where you live.

Updated · How we check our numbers

These are example numbers. Put in yours.

Your system

Equipment
tons

On the outdoor unit's model number: 24 = 2 tons, 36 = 3, 48 = 4, 60 = 5.

Old unit's rating
SEER

On the yellow EnergyGuide label or the AHRI certificate. Units from the 1990s are often 10.

The new one

SEER2
¢/kWh

Leave blank for your state's average.

$

Yearly savings

$841 a year

A 3-ton air conditioner in Texas uses about 12,918 kWh a year at 9.5 SEER2 and 7,670 at 16. At 16¢ a kWh that's $841 a year, paying back $1500 extra in 1.8 years.

Old
12,918 kWh9.5 SEER2
New
7,670 kWh16 SEER2
Saved
$841a year
Payback
1.8 years

Estimate for planning only, not professional advice. Check the manufacturer’s instructions, your local code and a licensed professional before you buy, build or install. Use at your own risk. Terms.

What it costs installed3 tons, NREL cost data

old = 10 SEER × 0.95 = 9.5 SEER2

cooling = 36,000 Btu/h × 3,409 h ÷ SEER2 ÷ 1000

saved = 5,248 kWh × 16¢ = $841

Other efficiencies

3 tons, Southeast
  • 14.3 SEER28,582 kWh a year
    $1,376/yr

    The Southeast minimum for new equipment.

  • 15 SEER28,182 kWh a year
    $1,312/yr

    Saves $759 a year against your old one.

  • 16 SEER27,670 kWh a year
    $1,230/yr

    Saves $841 a year against your old one.

  • 17 SEER27,219 kWh a year
    $1,157/yr

    Saves $914 a year against your old one.

  • 18 SEER26,818 kWh a year
    $1,093/yr

    Saves $978 a year against your old one.

  • 20 SEER26,136 kWh a year
    $984/yr

    Saves $1,087 a year against your old one.

Hours we used

DOE's averages for the Southeast: 3,409 cooling hours a year at full output. Your own bills are a better guide if your summers are milder or harsher than average.

Old ratings

Ratings before 2023 used a different test. We converted with AHRI's factors for ducted split systems: SEER × 0.95.

How we work it out

kWh a year = Btu/h × hours ÷ SEER2 ÷ 1,000 (plus Btu/h × heating hours ÷ HSPF2 ÷ 1,000 for a heat pump)

Hours are DOE's averages from its 2016 technical study, as the Federal Energy Management Program uses them: a central AC runs 3,409 full-load hours a year in the Southeast, 1,599 in the Southwest and 1,705 in the North. Heat pumps: 3,259 + 854 heating, 3,285 + 642, and 2,222 + 1,241. FEMP's own tables come out exactly with this formula.

Ratings before 2023 used a different test. DOE says SEER and SEER2 aren't directly comparable; AHRI's factors, adopted by RESNET, are SEER2 = 0.95 × SEER and HSPF2 = 0.85 × HSPF for ducted split systems. Since 2023, new split ACs must be 13.4 SEER2 in the North and 14.3 (13.8 at 45,000 Btu/h and up) in the Southeast and Southwest; split heat pumps 14.3 SEER2 and 7.5 HSPF2.