Calculators / Vents and chimneys
Dryer vent length: is your run too long, and what does cleaning cost?
Put in the duct length, the elbows and your dryer. You’ll get what the run counts as under the code’s 35 ft limit, what your dryer’s maker allows for it, and each price guide’s cleaning cost side by side.
Updated · How we check our numbers
Maker’s chart only
Counts as 37 ft
Your 22 ft run with 3 elbows counts as 37 ft: over the IRC’s 35 ft, but within Whirlpool’s limit of 35 ft of duct (the actual length, not counted with elbows) for rigid 4 in with 3 elbows.
- Run
- 22 ft3 elbows
- Code counts it as
- 37 ftlimit 35 ft
- Whirlpool allows
- 35 ft
- Cleaning
- $80 to $510
Estimate for planning only, not professional advice. Check the manufacturer’s instructions, your local code and a licensed professional before you buy, build or install. Use at your own risk. Terms.
Will the dryer fit?The laundry space, door swing and stacking
The air ducts too?When the EPA says to clean them, and what it costs
Code: 22 ft + 3 × 5 ft + 0 × 2.5 ft = 37 ft equivalent (Table M1502.4.6.1)
Whirlpool: 3 elbows on its chart → 35 ft; your run is 22 ft
Fixr: first floor → $100 to $175
Bob Vila: basement or first floor → $80 to $150
Thumbtack: national range → $186 to $510
Fixr by the foot: 22 ft × $6 to $11 = $130 to $240 (shown, not in the headline)
Your run against the code and each maker’s chart
22 ft, 3 elbows- IRC M1502.4.6 (M1502.4.5 before 2021)22 ft + 3 × 5 ft + 0 × 2.5 ft (4 in radius mitered elbows, Table M1502.4.6.1) = 37 ft of 352 ft over
- Whirlpool 27 in dryersWhirlpool: 35 ft of rigid 4 in duct with 3 elbows (box or louvered 4 in hood)Within 35 ft
- Whirlpool long vent (29 in, WED4890X)Whirlpool: 90 ft of rigid 4 in duct with 3 elbows (any hood)Within 90 ft
- GE long vent (GTD33 to GTD65, GTX22 to GTX65)GE: 70 ft of rigid 4 in duct with 3 elbows (box or louvered 4 in hood)Within 70 ft
- LG (DLE3600, DLEX4000 series)LG: 36 ft of rigid 4 in duct with 3 elbows (box or louvered 4 in hood)Within 36 ft
- Samsung (DVE45T3200W and similar)Samsung: 47 ft of rigid 4 in duct with 3 elbows (box or louvered 4 in hood)Within 47 ft
- Samsung long vent (DVE45T6020W)Samsung: 90 ft of rigid 4 in duct with 3 elbows (box or louvered 4 in hood)Within 90 ft
Each maker’s own chart for 4 in duct, read at your number of elbows. Your dryer’s installation instructions have the final say: charts change between models.
Dryer vent cleaning, by price guide
First floor vent- Fixr, Jan 2025First floor vent$100 to $180
- Bob Vila, Apr 2024Basement or first floor, quoting Angi and HomeAdvisor$80 to $150
- Thumbtack, Jul 2026What pros quoted, any location (“most people pay around $307”)$190 to $510
- Fixr, Jan 2025By the foot, “when deep cleaning is required for long vents”: $6 to $11 a ft × 22 ft. Most charge by the hour, it says, so this is out of the range above$130 to $240
Side by side: $80 to $510, from the lowest guide’s low to the highest guide’s high. It isn’t an average.
If it needs more than cleaning
- Fixr, Jan 2025A clogged vent$100 to $200
- Fixr, Jan 2025Wet lint in the vent$100 to $300
- Fixr, Jan 2025A bird nest removed$150 to $400
- Fixr, Jan 2025Inspecting the vent (Bob Vila gives the same, often included with cleaning)$30 to $60
- Bob Vila, Apr 2024Rerouting the vent or installing a new one$200 to $500
- Bob Vila, Apr 2024New duct or vent installed, by size and distance$180 to $600
- Bob Vila, Apr 2024Vent repair$80 to $150
- Bob Vila, Apr 2024Bird guard on the outside hood$30 to $100
Each guide’s own figure for the job, never added to the cleaning price.
The code lets the dryer maker’s instructions set the length instead (M1502.4.6.2), but the building inspector gets a copy of them for your make and model, and a run over 35 ft equivalent needs a permanent label giving its length within 6 ft of the duct connection (M1502.4.7). Check that your local code has the same sections.
The NFPA: “Once a year, or more often if you notice that it is taking longer than normal for your clothes to dry, clean lint out of the vent pipe or have a dryer lint removal service do it for you.” The CPSC: “Clean the dryer vent and exhaust duct periodically.” Whirlpool’s Use & Care Guide: “at least every 2 years.” LG: “periodically by qualified service personnel.” The USFA’s pages give no interval.
The U.S. Fire Administration: “Failure to clean (31%) was the leading factor contributing to the ignition of clothes dryer fires in homes from 2018-2020.” It says to clean the lint filter before and after each cycle and check that the vent behind the dryer isn’t damaged, crushed or restricted.
Count every bend from the back of the dryer to the outside hood. The makers’ charts count 90° elbows; a dryer that exhausts out the side or bottom has one more inside it. Only GE says what a 45 counts as (two make one 90). The code’s table gives each elbow its own length: 5 ft for the common 4 in radius mitered 90, much less for a smooth long-radius one.
How we work it out
The code: 35 ft, less the fittings
The International Residential Code limits a dryer exhaust duct to “35 feet ... from the connection to the transition duct from the dryer to the outlet terminal,” and “where fittings are used, the maximum length of the exhaust duct shall be reduced.” We read it in Seattle's adopted 2021 code, where it is section M1502.4.6.1; the 2015 and 2018 editions number it M1502.4.5.1. Its table counts a 4 in radius mitered 90° elbow as 5 ft and a 45° as 2 ft 6 in; smooth long-radius elbows count for less (1 ft 9 in down to 1 ft 6 in for a 90).
equivalent length = duct length + each elbow’s length from Table M1502.4.6.1
The same section lets the dryer maker's installation instructions set the length instead, with a copy for the inspector, and any run over 35 ft equivalent needs a permanent label giving its length within 6 ft of the connection. The duct itself must be smooth-walled metal, 4 in; a semi-rigid or foil connector behind the dryer can be one listed piece up to 8 ft, never inside a wall.
The makers: their own charts
Each maker prints a maximum length for 4 in duct by the number of 90° elbows, and every one says a dryer that exhausts out the side or bottom has one more turn inside it. Longer charts come with “long vent” models. Only GE says what a 45 counts as: “Two 45° turns within the duct length should be treated as a 90° elbow”; for the others we count each 45 as a full elbow, the strict reading. LG says not to use more than four 90° elbows and caps flexible metal duct at 8 ft in total. Charts change between models, so the one in your dryer's instructions has the final say. Check the room for the dryer itself with the washer and dryer fit calculator.
How often, and what cleaning costs
The U.S. Fire Administration says failure to clean was the leading factor in home dryer fires from 2018 to 2020 (31%). The NFPA says to clean lint out of the vent pipe “once a year, or more often if you notice that it is taking longer than normal for your clothes to dry.” The CPSC says to clean the vent and exhaust duct periodically, and to replace plastic or foil accordion duct with rigid or corrugated semi-rigid metal. Whirlpool's Use & Care Guide says at least every 2 years.
Cleaning prices are each guide's figure for where your vent comes out: Fixr and Bob Vila by floor, Thumbtack for any vent. The range runs from the lowest low to the highest high, never an average. Fixr's $6 to $11 a foot is for long vents that need deep cleaning, so it's shown but kept out. Dryer vent cleaning is often sold with air duct cleaning, which the EPA says to do only as needed. LawnStarter's page refused our reader; This Old House and Modernize have none. Read November 9, 2026.
Where the numbers come from
- Seattle Residential Code 2021, Chapter 15 (IRC M1502)
- Seattle Residential Code 2018, Chapter 15
- Whirlpool WGD9200S/WGD9400S dimension guide (W10110851A)
- Whirlpool WED4890X dimension guide (long vent models)
- GE GTD58EBSVWS quick specs (revised 12/22)
- LG DLE3600/DLEX4000 series owner’s manual (MFL70442647)
- Samsung DVE45T3200W specifications sheet
- Samsung DVE45T6020W specifications sheet
- Whirlpool dryer Use & Care Guide (8318480B)
- USFA: appliance and electrical fires
- USFA: clothes dryer fire safety flyer
- NFPA: clothes dryer and washing machine safety tips
- CPSC: overheated clothes dryers can cause fires (Pub. 5022)
- Fixr: dryer vent cleaning cost (Jan 2025)
- Bob Vila: dryer vent cleaning cost (Apr 2024)
- Thumbtack: dryer vent cleaning cost (Jul 2026)
Laundry and vents
Upkeep
More calculators
- Chimney repair costWhat does a chimney sweep, inspection, cap, crown or liner cost?
- Fireplace insert sizeWhich inserts fit my fireplace, and do the hearth, mantel and chimney meet code?
- Well water testWhat do my well water test results mean?
- Water softener sizeWhat size water softener do I need?
- RO waste waterHow much water does my reverse osmosis system waste?
- Gutter sizeDo I need 5 or 6 inch gutters, and how many downspouts?
- Bathroom layoutDoes my bathroom layout meet code clearances?
- Bidet plannerBidet seat, attachment or smart toilet: which fits my toilet?