Guides / Bathroom · Updated

Towel bar and grab bar height

From the 2010 ADA Standards and NKBA's bathroom guidelines, read November 2026. In a house, these are a guide, not the law.

Short answer

Grab bars go 33 to 36 in off the floor, measured to the top of the bar. No code sets a towel bar height, and the makers we read leave it to you. Keep it between 15 and 48 in, where anyone can reach it, and at least 12 in above a grab bar.

Bathroom accessory heights

WhatHeightSource
Grab bar33 to 36 in to the top of the barADA 609.4; NKBA guideline 14
Lower grab bar in a tub8 to 10 in above the rimADA 607.4
Grab bars for children18 to 27 inADA 609.4, at toilets for children
Anything above a grab bar12 in clear over itADA 609.3
Towel bars, hooks, soap dishes15 to 48 inNKBA guideline 23 (access); the ADA reach range, 308
Toilet paper holderCentred 26 in, 8 to 12 in ahead of the bowlNKBA guideline 23
Shelves40 to 48 inADA 603.4
Mirror over a sinkBottom edge 40 in maxADA 603.3

Towel bar height

We looked for a number and didn't find one. Moen's towel bar instructions say to "position the mounting template on the wall in the desired location"; DXV's say "determine desired height and location (optional)". The 2012 IRC gives no height for towel bars, and NKBA only says to put towel holders "conveniently located near all bath fixtures".

Two numbers do bear on it. NKBA's access standard puts accessories 15 to 48 in off the floor, the same reach range the ADA uses (15 in low, 48 in high). And the ADA wants 12 in of clear space above a grab bar, so a towel bar over a grab bar at 36 in starts no lower than 48 in. DXV says its bars work best screwed into a stud or cross brace.

Grab bar height

The ADA puts grab bars "33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface" (609.4). NKBA recommends the same 33 to 36 in. The bar is 1¼ to 2 in round, 1½ in off the wall, and it and its mounting have to hold 250 lb pushed down or sideways at any point (609.8).

By the toilet: one on the side wall, at least 42 in long, no more than 12 in from the back wall and reaching at least 54 in out from it; one on the wall behind, at least 36 in long, running 12 in past the toilet's centre on one side and 24 in on the other (604.5).

In a tub without a seat: two on the back wall, one at 33 to 36 in and one 8 to 10 in above the rim, each at least 24 in long; a 24 in bar on the end with the taps and a 12 in one at the head end, both at the front edge of the tub (607.4.2).

In a shower: a transfer shower gets bars across the control wall and along the back wall to 18 in from it (608.3.1). A roll-in shower gets them on three walls, or on the back and the wall across from a seat, never above the seat (608.3.2).

In a residential dwelling unit, the ADA lets you leave the tub and shower bars off as long as the walls are reinforced to take them later (607.4 and 608.3 exceptions). NKBA recommends reinforcing tub and shower walls for 250 lb when they're built.

Toilet paper holder height

NKBA: 8 to 12 in in front of the edge of the bowl, centred 26 in off the floor. The ADA: the holder's centre 7 to 9 in in front of the toilet and its outlet 15 to 48 in up, not behind a grab bar (604.7). More around the toilet in toilet rough-in and clearance.

Planning a whole bathroom

The bathroom layout calculator checks the floor: toilet, vanity, tub or shower, and the door. For turning space and the rest of the accessible numbers, see ADA bathroom dimensions; for shower seats and controls, walk-in shower dimensions.

Where the numbers come from

Get the new ones by email

We're adding more. Put your email in and we'll send one short note each time there's a new calculator on any of our sites.

No spam. Unsubscribe any time.