Guides / Bathroom · Updated
Walk-in shower dimensions
Code minimums from the 2012 IRC, NKBA's recommendations, and the shower bases American Standard sells, read November 2026.
Short answer
The smallest shower code allows is 30 in across inside and 900 sq in, so 30 × 30 in, with a way in at least 22 in wide and 24 in clear in front of it. NKBA recommends 36 × 36 in. For a walk-in shower in place of a tub, American Standard's 60 in bases, 30 to 36 in deep, take the alcove tub's footprint; it also sells 48 in ones.
Minimum shower size
The code's words: shower compartments "shall have not less than 900 square inches (0.6 m2) of interior cross-sectional area" and be "not less than 30 inches (762 mm) in minimum dimension measured from the finished interior dimension" (2012 IRC P2708.1). A narrower shower is allowed down to 25 in across if it has at least 1,300 sq in. The way in needs "a clear and unobstructed finished width of not less than 22 inches" (P2708.1.1), and a hinged shower door has to open outward.
Measure inside the finished walls, at the height of the threshold. A fold-down seat is allowed if the shower still has its 900 sq in with the seat up. The walls need a water-resistant finish at least 6 ft up from the floor (R307.2).
The IRC sections we read size every shower the same way, so a walk-in or curbless shower meets the same minimums as one with a door.
Standard shower sizes
The shower bases American Standard sells on its own store, outside dimensions. The inside is smaller by the walls, so check the spec sheet.
| Size | American Standard line | Area | NKBA 36 × 36? |
|---|---|---|---|
| 48 × 34 in | Princeton | 1,632 sq in | 2 in narrow |
| 48 × 36 in | Princeton, Townsend | 1,728 sq in | Yes |
| 60 × 30 in | Princeton, Townsend, Ovation Curve | 1,800 sq in | 6 in narrow |
| 60 × 32 in | Princeton, Passage, Aspirations, Townsend | 1,920 sq in | 4 in narrow |
| 60 × 34 in | Princeton | 2,040 sq in | 2 in narrow |
| 60 × 36 in | Princeton | 2,160 sq in | Yes |
| 38 × 38 in | Townsend ADA (sold as ADA) | 1,444 sq in | Yes |
| 64 × 34 in | Townsend ADA (sold as ADA) | 2,176 sq in | 2 in narrow |
Every one of these is over the code minimum on paper. A 60 × 30 in base is the footprint of the common alcove tub (see bathtub sizes), so it can go where a tub came out. The shower-base collection on American Standard's store lists no 32 or 36 in square bases; its smallest square one is the 38 in ADA base.
Room around the shower
Code wants 24 in clear in front of the opening (Figure R307.1); NKBA recommends 30 in in front of every fixture. Here's a 60 × 32 in shower across the end of a 98 × 60 in bathroom, checked and drawn by our bathroom layout calculator:
Plan view, the back wall at the top. Shaded strips are code's clear space in front of each fixture (red where it's short); dashed is the door's swing. The toilet is drawn 15.16 in wide, from the Brondell Sutro spec sheet; yours may differ.
The opening has to land in the part of the shower's side that the toilet doesn't stand in front of. Put your own room in the calculator to see where yours can go.
Accessible and curbless showers
The ADA sizes two kinds. A transfer shower is 36 × 36 in inside with a 36 in entry and 36 × 48 in clear outside it. A roll-in shower is at least 30 × 60 in with a 60 in entry, or 36 × 60 in with a 36 in entry at one end. A roll-in threshold is 0.5 in high at most. NKBA says a 60 in deep roll-in shower can do with a 32 in entry, and a 42 in deep one needs 36 in.
Controls go 38 to 48 in off the floor (NKBA, and the ADA for a transfer shower), and a seat 17 to 19 in high and 15 in deep. Grab bar heights are in towel bar and grab bar height; the rest in ADA bathroom dimensions.
Where the numbers come from
- 2012 IRC, P2708.1, P2708.1.1, R307.1 and R307.2, from Public.Resource.Org (ICC's 2021 viewer refused our reader)
- NKBA Bathroom Planning Guidelines, guidelines 4, 9, 10 and 12
- American Standard shower bases
- 2010 ADA Standards, 608