What size furnace do I need?
A furnace is sized by its heat output against your house’s heat loss on the coldest design day. Put in the Manual J number and get the output range, and the furnaces that land in it.
Updated · How we check our numbers
Buy a furnace in this output range
52,000 Btu/h to 72,800 Btu/h output
Your 52,000 Btu/h heat loss puts the furnace's output between 52,000 Btu/h and 72,800 Btu/h. The smallest we list in that range is the Goodman GR9S920603BN: 60,000 Btu/h in, 55,260 Btu/h out (106% of the load).
- Heat loss
- 52,000 Btu/hManual J
- Smallest that fits
- 60kGoodman, 55,260 Btu/h out
- Models in range
- 3 of 17
As an Amazon Associate we earn from qualifying purchases.
Estimate for planning only, not professional advice. Check the manufacturer’s instructions, your local code and a licensed professional before you buy, build or install. Use at your own risk. Terms.
What it costs60,000 Btu/h furnace installed, NREL cost data
Or a heat pumpWhich heat pumps cover this load
52,000 × 100% to 52,000 × 140% = 52,000 Btu/h to 72,800 Btu/h of output
Condensing furnaces (92%+ AFUE)
maker spec sheets- Goodman GR9S920603BN60,000 Btu/h in, 55,260 Btu/h out, 92.1% AFUEIn range
106% of your heat loss.
- Carrier 59SC5B060E1460,000 Btu/h in, 58,000 Btu/h out, 95% AFUEIn range
112% of your heat loss.
- Goodman GR9S960603BN60,000 Btu/h in, 58,200 Btu/h out, 97% AFUEIn range
112% of your heat loss.
- Goodman GR9S920803BN80,000 Btu/h in, 73,680 Btu/h out, 92.1% AFUEAllowed with AC
142% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.
- Goodman GR9S960805CN80,000 Btu/h in, 77,600 Btu/h out, 97% AFUEAllowed with AC
149% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.
- Carrier 59SC5B080E1780,000 Btu/h in, 78,000 Btu/h out, 96.5% AFUEAllowed with AC
150% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.
- Goodman GR9S921004CN100,000 Btu/h in, 92,100 Btu/h out, 92.1% AFUEAllowed with AC
177% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.
- Goodman GR9S961005CN100,000 Btu/h in, 96,100 Btu/h out, 96.1% AFUEAllowed with AC
185% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.
- Carrier 59SC5B100E21100,000 Btu/h in, 97,000 Btu/h out, 96.3% AFUEAllowed with AC
187% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.
- Goodman GR9S921205DN120,000 Btu/h in, 110,520 Btu/h out, 92.1% AFUEAllowed with AC
213% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.
- Goodman GR9S961205DN120,000 Btu/h in, 114,000 Btu/h out, 95% AFUEAllowed with AC
219% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.
- Carrier 59SC5B120E24120,000 Btu/h in, 116,000 Btu/h out, 96.1% AFUEAllowed with AC
223% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.
- Carrier 59SC5B140E24140,000 Btu/h in, 135,000 Btu/h out, 95% AFUEAllowed with AC
260% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.
4 more that don't work
- Carrier 59SC5B026E1426,000 Btu/h in, 25,000 Btu/h out, 96% AFUEToo small
48% of your heat loss: short by 27,000 Btu/h.
- Goodman GR9S920403AN40,000 Btu/h in, 36,840 Btu/h out, 92.1% AFUEToo small
71% of your heat loss: short by 15,160 Btu/h.
- Goodman GR9S960403AN40,000 Btu/h in, 38,800 Btu/h out, 97% AFUEToo small
75% of your heat loss: short by 13,200 Btu/h.
- Carrier 59SC5B040E1440,000 Btu/h in, 39,000 Btu/h out, 96% AFUEToo small
75% of your heat loss: short by 13,000 Btu/h.
Natural gas ratings from Goodman’s and Carrier’s spec sheets, November 2026. Each maker has more cabinet widths and blower sizes at most outputs.
80,000 Btu/h output is 154% of the heat loss, above the window: a like-for-like swap would keep it oversized.
The Manual J should use a 99% heating design temperature no colder than 5 °F here. ENERGY STAR sets that as the county's limit, from the coldest weather station nearby, and EPA recommends the Manual J value for the station closest to the house.
The big number on a furnace (40,000, 60,000, 80,000) is the gas it burns. What heats the house is the output: about 80% of that on an 80% AFUE furnace, 92 to 97% on a condensing one. ENERGY STAR compares output with the heat loss, and for a two-stage or modulating furnace uses “the maximum output available”.
Output 100 to 140% of the Manual J heat loss for a furnace that only heats. Paired with central AC, 100 to 140% is recommended and up to 400% allowed, because the blower may need to be bigger for the cooling airflow. A heat loss of 10,000 Btu/h or less may use up to a 40,000 Btu/h furnace.
Goodman’s sheets: “reduce input rating by 3% for each 1000’ above 2000’ altitude”. Output drops with it, so check the maker’s high-altitude rating above 2,000 ft.
How we work it out
heat loss × 100% ≤ furnace output ≤ heat loss × 140%
The heat loss comes from an ACCA Manual J for your house at your winter design temperature. The International Residential Code (M1401.3) requires equipment sized by Manual S from Manual J loads, so there's no square-feet rule here: we looked for one from ACCA, DOE, ENERGY STAR and the makers and didn't find one we could stand behind. The Manual J guide covers what goes into one.
The window
ENERGY STAR's HVAC design rules, Table 3: a furnace that only heats should put out 100 to 140% of the heat loss. Paired with central AC, 100 to 140% is recommended and up to 400% allowed, because the furnace's blower moves the cooling air too. A heat loss of 10,000 Btu/h or less may use a furnace up to 40,000 Btu/h. For two-stage and modulating furnaces, ENERGY STAR uses the maximum output.
Input and output
A furnace's model number gives its input, the gas it burns. Output is what reaches the house: 32,000 Btu/h from Goodman's 40,000 Btu/h 80% furnace, 38,800 from its 97% one. We compare output, from each maker's spec sheet.
Design temperature by ZIP
From EPA's ENERGY STAR reference guide (2019 edition), which gives every county the coldest 99% heating design temperature among the ASHRAE and Manual J weather stations in it or within 40 miles of its center. We use the county that holds most of your ZIP. It's the coldest a Manual J for an ENERGY STAR home may use; EPA recommends the value for the station closest to the house.
Where the numbers come from
- ENERGY STAR: National HVAC Design Supplement to Std. 310, Rev. 13 (sizing limits)
- ENERGY STAR: Design Temperature Limit Reference Guide (2019 Edition)
- Pima County, AZ: HVAC sizing requirements (quotes IRC M1401.3)
- ACCA: Manual J
- Goodman GR9S80 spec sheet
- Goodman GR9S92 spec sheet
- Goodman GR9S96 spec sheet
- Carrier Comfort 59SC5B product data
Heating and cooling
More calculators
- Heat pump sizeWhich heat pumps cover my house at my design temperature, and how much backup heat?
- Mini-split sizingWhat size mini-split heats and cools my garage or room?
- BTU to tonsHow many tons is my BTU number, and which mini-split is that?
- AC sizeWhat size AC do I need? What goes into a Manual J, and checking a quote.
- SEER2 savingsHow much will a higher SEER2 AC or heat pump save?
- AC unit costWhat does a new AC unit, heat pump or furnace cost installed?
- Dehumidifier sizingWhat capacity keeps my garage or basement dry?
- Air filter sizeWhat size furnace or AC filter, which MERV, and how often to change it?