What size furnace do I need?

A furnace is sized by its heat output against your house’s heat loss on the coldest design day. Put in the Manual J number and get the output range, and the furnaces that land in it.

Updated · How we check our numbers

These are example numbers. Put in yours.

Your house

Btu/h

The total heat loss on the Manual J report. Leave blank if you don’t have one yet.

°F

Look up your ZIP above, or read it off the Manual J.

The furnace

Efficiency
Central AC on the same blower
Btu/h

On the rating plate inside the door, as output or heating capacity.

Buy a furnace in this output range

52,000 Btu/h to 72,800 Btu/h output

Your 52,000 Btu/h heat loss puts the furnace's output between 52,000 Btu/h and 72,800 Btu/h. The smallest we list in that range is the Goodman GR9S920603BN: 60,000 Btu/h in, 55,260 Btu/h out (106% of the load).

Heat loss
52,000 Btu/hManual J
Smallest that fits
60kGoodman, 55,260 Btu/h out
Models in range
3 of 17
See gas furnaces on Amazon (opens Amazon in a new tab)

As an Amazon Associate we earn from qualifying purchases.

Estimate for planning only, not professional advice. Check the manufacturer’s instructions, your local code and a licensed professional before you buy, build or install. Use at your own risk. Terms.

What it costs60,000 Btu/h furnace installed, NREL cost data

Or a heat pumpWhich heat pumps cover this load

52,000 × 100% to 52,000 × 140% = 52,000 Btu/h to 72,800 Btu/h of output

Condensing furnaces (92%+ AFUE)

maker spec sheets
  • Goodman GR9S920603BN60,000 Btu/h in, 55,260 Btu/h out, 92.1% AFUE
    In range

    106% of your heat loss.

  • Carrier 59SC5B060E1460,000 Btu/h in, 58,000 Btu/h out, 95% AFUE
    In range

    112% of your heat loss.

  • Goodman GR9S960603BN60,000 Btu/h in, 58,200 Btu/h out, 97% AFUE
    In range

    112% of your heat loss.

  • Goodman GR9S920803BN80,000 Btu/h in, 73,680 Btu/h out, 92.1% AFUE
    Allowed with AC

    142% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.

  • Goodman GR9S960805CN80,000 Btu/h in, 77,600 Btu/h out, 97% AFUE
    Allowed with AC

    149% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.

  • Carrier 59SC5B080E1780,000 Btu/h in, 78,000 Btu/h out, 96.5% AFUE
    Allowed with AC

    150% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.

  • Goodman GR9S921004CN100,000 Btu/h in, 92,100 Btu/h out, 92.1% AFUE
    Allowed with AC

    177% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.

  • Goodman GR9S961005CN100,000 Btu/h in, 96,100 Btu/h out, 96.1% AFUE
    Allowed with AC

    185% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.

  • Carrier 59SC5B100E21100,000 Btu/h in, 97,000 Btu/h out, 96.3% AFUE
    Allowed with AC

    187% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.

  • Goodman GR9S921205DN120,000 Btu/h in, 110,520 Btu/h out, 92.1% AFUE
    Allowed with AC

    213% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.

  • Goodman GR9S961205DN120,000 Btu/h in, 114,000 Btu/h out, 95% AFUE
    Allowed with AC

    219% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.

  • Carrier 59SC5B120E24120,000 Btu/h in, 116,000 Btu/h out, 96.1% AFUE
    Allowed with AC

    223% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.

  • Carrier 59SC5B140E24140,000 Btu/h in, 135,000 Btu/h out, 95% AFUE
    Allowed with AC

    260% of your heat loss: over the recommended 140%, inside the 400% allowed when the furnace's blower also has to move the AC's air.

4 more that don't work
  • Carrier 59SC5B026E1426,000 Btu/h in, 25,000 Btu/h out, 96% AFUE
    Too small

    48% of your heat loss: short by 27,000 Btu/h.

  • Goodman GR9S920403AN40,000 Btu/h in, 36,840 Btu/h out, 92.1% AFUE
    Too small

    71% of your heat loss: short by 15,160 Btu/h.

  • Goodman GR9S960403AN40,000 Btu/h in, 38,800 Btu/h out, 97% AFUE
    Too small

    75% of your heat loss: short by 13,200 Btu/h.

  • Carrier 59SC5B040E1440,000 Btu/h in, 39,000 Btu/h out, 96% AFUE
    Too small

    75% of your heat loss: short by 13,000 Btu/h.

Natural gas ratings from Goodman’s and Carrier’s spec sheets, November 2026. Each maker has more cabinet widths and blower sizes at most outputs.

Your old furnace

80,000 Btu/h output is 154% of the heat loss, above the window: a like-for-like swap would keep it oversized.

Design temperature

The Manual J should use a 99% heating design temperature no colder than 5 °F here. ENERGY STAR sets that as the county's limit, from the coldest weather station nearby, and EPA recommends the Manual J value for the station closest to the house.

Compare output, not input

The big number on a furnace (40,000, 60,000, 80,000) is the gas it burns. What heats the house is the output: about 80% of that on an 80% AFUE furnace, 92 to 97% on a condensing one. ENERGY STAR compares output with the heat loss, and for a two-stage or modulating furnace uses “the maximum output available”.

ENERGY STAR’s window

Output 100 to 140% of the Manual J heat loss for a furnace that only heats. Paired with central AC, 100 to 140% is recommended and up to 400% allowed, because the blower may need to be bigger for the cooling airflow. A heat loss of 10,000 Btu/h or less may use up to a 40,000 Btu/h furnace.

High altitude

Goodman’s sheets: “reduce input rating by 3% for each 1000’ above 2000’ altitude”. Output drops with it, so check the maker’s high-altitude rating above 2,000 ft.

How we work it out

heat loss × 100% ≤ furnace output ≤ heat loss × 140%

The heat loss comes from an ACCA Manual J for your house at your winter design temperature. The International Residential Code (M1401.3) requires equipment sized by Manual S from Manual J loads, so there's no square-feet rule here: we looked for one from ACCA, DOE, ENERGY STAR and the makers and didn't find one we could stand behind. The Manual J guide covers what goes into one.

The window

ENERGY STAR's HVAC design rules, Table 3: a furnace that only heats should put out 100 to 140% of the heat loss. Paired with central AC, 100 to 140% is recommended and up to 400% allowed, because the furnace's blower moves the cooling air too. A heat loss of 10,000 Btu/h or less may use a furnace up to 40,000 Btu/h. For two-stage and modulating furnaces, ENERGY STAR uses the maximum output.

Input and output

A furnace's model number gives its input, the gas it burns. Output is what reaches the house: 32,000 Btu/h from Goodman's 40,000 Btu/h 80% furnace, 38,800 from its 97% one. We compare output, from each maker's spec sheet.

Design temperature by ZIP

From EPA's ENERGY STAR reference guide (2019 edition), which gives every county the coldest 99% heating design temperature among the ASHRAE and Manual J weather stations in it or within 40 miles of its center. We use the county that holds most of your ZIP. It's the coldest a Manual J for an ENERGY STAR home may use; EPA recommends the value for the station closest to the house.