Calculators / Drywall, paint and lighting
Recessed lighting calculator
Put in the room, the ceiling height, what the room is for and the light size. You get how many pot lights, in how many rows, how far apart and how far from the walls, the light they give, and a ceiling plan to scale.
Updated · How we check our numbers
Your 14x12 room
12 four-inch lights, 3 ft 6 in apart
Your 14x12 room with an 8 ft ceiling: 12 four-inch lights in three rows of four, 3 ft 6 in apart along the 14 ft walls and 4 ft across, 1 ft 9 in and 2 ft from the walls. About 8,136 lumens in all.
- Lights
- 123 × 4
- Apart
- 3 ft 6 in4 ft across
- From the walls
- 1 ft 9 in2 ft on the long walls
- Light
- 8,136lumens in all
Estimate for planning only, not professional advice. Check the manufacturer’s instructions, your local code and a licensed professional before you buy, build or install. Use at your own risk. Terms.
Ceiling fan sizeA fan for the same room: blade span and downrod for this ceiling.
Paint the roomGallons for the walls and ceiling, by maker.
spacing = 8 ft ceiling ÷ 2 = 4 ft at most (Philips Hue)
along 14 ft: 14 ÷ 4, rounded up = 4 → 3 ft 6 in apart, 1 ft 9 in from the wall
across 12 ft: 12 ÷ 4, rounded up = 3 → 4 ft apart, 2 ft from the wall
lights = 4 × 3 = 12
check: spacing criterion 1.33 × 8 ft to the floor = 10.6 ft widest
lumens = 12 × 678 lm = 8,136 lumens, 48.4 a sq ft
Dots: the lights. Dashed: the rows, 3 ft 6 in apart along the 14 ft side and 4 ft across, with half a space to each wall.
4 vs 6 in: what the spec sheets say
12 lights- Halo HLB4 MicroEdge4 in · 678 lm at 3000K · 9.67 W · 4 to 4¼ in hole · spacing criterion 1.338,136 lm
12 of them: 8,136 lumens, 48.4 a sq ft, 116 W.
- Halo HLB6 MicroEdge6 in · 951 lm at 3000K · 13.3 W · 6 to 6¼ in hole · spacing criterion 1.2911,412 lm
The 6 in size, for comparison: 11,412 lumens from 12.
- Halo Home BLD6 (retrofit)6 in · 819 lm at 3000K · 9.3 W · into a 5 or 6 in can · spacing criterion 1.269,828 lm
The 6 in size, for comparison: 9,828 lumens from 12.
- Lithonia WF6E wafer6 in · 791 lm at 3000K · 11.2 W · 6 in hole, 6¼ in at most9,492 lm
The 6 in size, for comparison: 9,492 lumens from 12.
Lumens at 3000K from each maker’s photometric test. A 4 in light gives less light each, so the same grid is dimmer; it doesn’t change the spacing.
Philips Hue puts lights 1.5 to 2 ft from the wall on an 8 ft ceiling, and half a space lands inside that.
Philips Hue's ceiling ÷ 2 is a close spacing. The 4 in spec sheets we read give a spacing criterion of 1.33 or more, and spacing criterion × mounting height estimates the spacing that still lights the floor evenly: 1.3 × 8 ft = 10.6 ft. That allows as few as 4 (2 × 2), 7 ft apart. Fewer lights give less light in all, so check the lumens below.
For a picture wall or a work spot, Philips Hue spaces lights about 3 ft apart; to wash a wall evenly, 1.5 to 2 ft from it.
If insulation will touch the fixture, buy one marked IC. Halo’s HLB4 and HLB6 sheets say “UL Certified type IC suitable for direct contact with air permeable insulation” but “Not recommended for use in direct contact with spray foam insulation”; Lithonia’s WF6E is “approved for direct contact with insulation.” Halo’s sheets allow them in clothes closets only when installed to the NEC 410.16 spacing; the code text itself is behind NFPA’s login.
How we work it out
Spacing. Philips Hue's layout guide divides the ceiling height by two: 4 ft apart on an 8 ft ceiling, 4.5 ft on 9 ft, 5 ft on 10 ft. We fit the fewest lights along each wall that keep them no farther apart than that, spread them evenly and leave half a space at each wall, so the grid sits square in the room.
lights along a wall = wall length ÷ (ceiling height ÷ 2), rounded up · spacing = wall length ÷ lights · wall gap = spacing ÷ 2
Distance from the wall. Hue's examples put lights 1.5 to 2 ft from the wall on an 8 ft ceiling, 2 ft on 9 ft and 2 to 2.5 ft on 10 ft. We check half a space against those and say when a small room puts lights closer.
Fewest lights. Each Halo spec sheet gives a spacing criterion, from 1.26 to 1.34 straight across. Spacing criterion times the height from the work plane to the light is the widest spacing that still lights it evenly. Hue's rule is much closer than that, so we show the fewest lights the sheets allow too: a smaller count, and less light in all.
widest spacing = spacing criterion × (ceiling − work plane)
4 vs 6 in. Size changes the light from each fixture, not the layout. Halo's 4 in HLB4 gives 678 lumens, its 6 in HLB6 951, the BLD6 retrofit 819 and Lithonia's 6 in WF6E 791, all at 3000K. We multiply by the count.
We found no IES, DOE or ENERGY STAR page we could read that gives the light a living room or kitchen needs, so we show the lumens a layout gives and don't call it enough or too little. Juno, WAC and Commercial Electric publish no layout guide we could find, and Home Depot's lumens page refused our reader.
Where the numbers come from
- Philips Hue (Signify): how far should recessed lights be from the wall? (read Nov 8 2026)
- Halo HLB4 MicroEdge 4 in spec sheet (read Nov 8 2026)
- Halo HLB6 MicroEdge 6 in spec sheet (read Nov 8 2026)
- Halo Home BLD6 (retrofit) 6 in spec sheet (read Nov 8 2026)
- Lithonia WF6E wafer 6 in spec sheet (read Nov 8 2026)
- e-Light (UNC Greensboro IARC): photometric distribution and spacing criteria (read Nov 8 2026)
The same room
More calculators
- Drywall calculatorHow many sheets of drywall, screws, buckets of mud and rolls of tape?
- Paint calculatorHow many gallons of paint for my room, and do I need primer?
- Feet and inchesAdd, subtract or convert lengths the way a tape reads them.
- Will it fit through the door?Will the couch, mattress or dresser get through the door, hall and stairs?
- Moving truck and storage sizeWhat size moving truck, storage unit or PODS for my home, and what fits in a 10x10?
- ADU costWhat does an ADU cost to build, with permit and fees?
- Fair market rentWhat could an ADU rent for in my ZIP code, and how long to pay back the build?
- Home warrantyIs a home warranty worth it for my house?