Calculators / Heating and cooling
Ceiling fan size calculator
Put in the room and the ceiling height. You get the blade span the fan makers’ charts agree on, whether one fan is enough, and the downrod that puts the blades about 8 to 9 ft up.
Updated · How we check our numbers
Your 14x12 room
One 50 to 52 in fan
Your 14x12 room: one 50 to 52 in fan, on the short rod in the box (3 to 6 in), so the blades sit about 8 to 9 ft up.
- Fans
- 1168 sq ft
- Blade span
- 50 to 52 in2 of 3 charts
- Downrod
- 3–6 in9 ft ceiling
As an Amazon Associate we earn from qualifying purchases.
Estimate for planning only, not professional advice. Check the manufacturer’s instructions, your local code and a licensed professional before you buy, build or install. Use at your own risk. Terms.
What it costs to runPut in the fan’s watts and hours at your state’s electricity price.
area = 14 × 12 ft = 168 sq ft
fans = 168 ÷ 400, rounded up = 1
span: Hunter 50 to 54 in · Westinghouse 42 to 52 in · Minka-Aire 60 in and up → 2 of 3 agree on 50 to 52 in
widest that fits = 12 ft × 12 − 2 × 30 in = 84 in
downrod: charts read at 9 ft → the short rod in the box (3 to 6 in)
Shaded: the blades. Ring: Hunter's 30 in from the blade tips to the nearest wall or obstruction.
What each chart says
168 sq ft a fan- Hunter400 sq ft row50 to 54 in
Agrees with the pick.
- Westinghouseup to 225 sq ft row42 to 52 in
Agrees with the pick.
- Minka-Aireover 160 sq ft row60 in and up
Reads this size differently.
Hunter, Westinghouse and Minka-Aire room charts. The pick is the size most of them agree on.
Mount it to a box listed and marked for fan support, fastened to a joist or a brace between joists. Per Mike Holt on NEC 314.27(C), a fan box can carry up to 70 lb, and a fan over 35 lb needs a box marked with the weight it holds. Hunter wants the fan directly below a joist or brace that holds the full weight.
For a 9 ft ceiling, Westinghouse: 3 or 6 in; Hunter: the standard downrod that comes with the fan. We give the shorter of the two, read at the whole foot at or below your ceiling, so the rod is never too long. Hunter aims for blades about 8 to 9 ft above the floor and never under 7 ft.
ENERGY STAR's 587 certified indoor fans at 52 in draw 12 to 99.8 W on high, 28.6 W in the middle. Look for the label: the list gives watts for every model.
Measure to where the fan hangs. Westinghouse says to use an extension downrod on an angled ceiling; Minka-Aire says most of its fans hang from up to an 18° pitch, and 45° with its slope kit.
How we work it out
Blade span. Hunter, Westinghouse and Minka-Aire each publish a room chart, and they read the same room differently: for 12 × 14 ft, Hunter says 50 to 54 in, Westinghouse 42 to 52 in and Minka-Aire 60 in and up. We show all three and pick the sizes most of them agree on.
How many fans. Westinghouse recommends two fans over 400 sq ft; we give one for each 400 sq ft or part of it. Hunter, citing UL and ETL, wants 30 in from the blade tips to the nearest wall, so a narrow room gets a smaller fan than its area suggests.
fans = area ÷ 400, rounded up · widest span = (narrower side × 12) − 60 in
Downrod. Hunter wants the blades about 8 to 9 ft above the floor and never under 7 ft. On an 8 ft ceiling that means a hugger (low-profile) fan. Above that, Hunter's and Westinghouse's downrod charts give a rod for each ceiling height; we read them at the whole foot at or below yours and give the shorter rod.
Where the numbers come from
- Hunter: room measurements (blade span by room size, 7 ft and 30 in clearances)
- Hunter: what downrod length should I purchase for my fan?
- Hunter: wet-rated vs damp-rated fans, what outdoor spaces need
- Hunter: owner’s guide 45068-01 (fan site, support and clearances)
- Westinghouse Lighting: 2018 catalog, ceiling fan size
- Westinghouse Lighting: 2018 catalog, extension down rod chart
- Minka-Aire: choosing the right ceiling fan (room size)
- Minka: FAQ (sloped ceilings)
- MacroAir: what size ceiling fan for an outdoor patio
- Big Ass Fans: Haiku Outdoor spec sheet
- EC&M Code Q&A (Mike Holt): boxes at ceiling-suspended fan outlets, NEC 314.27(C)
- ENERGY STAR: certified ceiling fans (dataset)
Heating and cooling
The same room
Outdoors
More calculators
- SEER2 savingsHow much will a higher SEER2 AC or heat pump save?
- AC unit costWhat does a new AC unit, heat pump or furnace cost installed?
- Dehumidifier sizingWhat capacity keeps my garage or basement dry?
- Air filter sizeWhat size furnace or AC filter, which MERV, and how often to change it?
- Air duct cleaningShould I have my air ducts cleaned, how often, and what does it cost?
- Dryer vent lengthIs my dryer vent too long for the code and my dryer, and what does cleaning cost?
- Chimney repair costWhat does a chimney sweep, inspection, cap, crown or liner cost?
- Fireplace insert sizeWhich inserts fit my fireplace, and do the hearth, mantel and chimney meet code?