Calculators / HVAC sizing
What size heat pump do I need?
A heat pump makes less heat as it gets colder, so its size is set by what it makes on your coldest design day, not by its tons. Put in your loads and design temperature and see which units cover them, and what backup heat the rest need.
Updated · How we check our numbers
Covers your heat loss at design
3 heat pumps cover it
At 10°F your house loses 36,000 Btu/h. The smallest unit we list that covers it without backup heat and stays inside ENERGY STAR’s cooling limits is the Mitsubishi Electric PUZ-HA36NKA1: 38,000 Btu/h at 5°F, 33,000 Btu/h of cooling.
- Heat loss
- 36,000 Btu/hManual J
- Design temperature
- 10°Fcompared at 5°F
- Heat gain
- 30,000 Btu/h2.5 ton
- Smallest that covers it
- 3 tonMitsubishi Electric PUZ-HA36NKA1
As an Amazon Associate we earn from qualifying purchases.
Estimate for planning only, not professional advice. Check the manufacturer’s instructions, your local code and a licensed professional before you buy, build or install. Use at your own risk. Terms.
What it costs3 ton heat pump installed, NREL cost data
Or a gas furnaceFurnace size for the same heat loss
capacity at 5°F ≥ 36,000 Btu/h heat loss
30,000 × 90% to 30,000 × 160% = 27,000 Btu/h to 48,000 Btu/h of cooling
Ducted heat pumps
NEEP ccASHP list- Mitsubishi Electric PUZ-HA36NKA1PVA-A36AA indoor · heat 40,000 at 47°F, 38,000 at 17°F, 38,000 at 5°F · cool 33,000 · ENERGY STAR cold climateCovers it
38,000 Btu/h at 5°F, 106% of your heat loss. Cooling 110% of the heat gain.
- Mitsubishi Electric PUZ-HA42NKA2PVA-A42AA indoor · heat 54,000 at 47°F, 48,000 at 17°F, 48,000 at 5°F · cool 42,000 · ENERGY STAR cold climateCovers it, big for cooling
48,000 Btu/h at 5°F, 133% of your heat loss. Cooling 140% of the heat gain.
- Carrier 38MURAQ48AB340MUAAQ48XA3 indoor · heat 50,000 at 47°F, 48,000 at 17°F, 46,000 at 5°F · cool 47,000 · ENERGY STAR cold climateCovers it, big for cooling
46,000 Btu/h at 5°F, 128% of your heat loss. Cooling 157% of the heat gain.
- Mitsubishi Electric PUZ-HA30NKA1PVA-A30AA indoor · heat 34,000 at 47°F, 32,000 at 17°F, 32,000 at 5°F · cool 30,000 · ENERGY STAR cold climate2 kW backup
32,000 Btu/h at 5°F, 4,000 Btu/h short of your heat loss. Cooling 100% of the heat gain.
- Goodman GSZV903610A*CA*F3743*6D* + MBVC1601 indoor · heat 34,200 at 47°F, 29,200 at 17°F, 24,400 at 5°F · cool 34,2004 kW backup
24,400 Btu/h at 5°F, 11,600 Btu/h short of your heat loss. Cooling 114% of the heat gain.
- Goodman GZV7SA3610A*AHVE48DP1300A* indoor · heat 35,000 at 47°F, 35,100 at 17°F, 29,000 at 5°F · cool 35,000 · ENERGY STAR cold climate3 kW backup
29,000 Btu/h at 5°F, 7,000 Btu/h short of your heat loss. Cooling 117% of the heat gain.
- Carrier 38MURAQ36AB340MUAAQ36XA3 indoor · heat 40,000 at 47°F, 47,000 at 17°F, 34,400 at 5°F · cool 36,000 · ENERGY STAR cold climate1 kW backup
34,400 Btu/h at 5°F, 1,600 Btu/h short of your heat loss. Cooling 120% of the heat gain.
- Goodman GSZV904810A*CA*F4961*6D* + MBVC2001 indoor · heat 44,500 at 47°F, 34,000 at 17°F, 25,400 at 5°F · cool 45,0004 kW backup
25,400 Btu/h at 5°F, 10,600 Btu/h short of your heat loss. Cooling 150% of the heat gain.
- Goodman GZV7SA4810A*AHVE60DP1300A* indoor · heat 47,500 at 47°F, 42,300 at 17°F, 33,600 at 5°F · cool 46,500 · ENERGY STAR cold climate1 kW backup
33,600 Btu/h at 5°F, 2,400 Btu/h short of your heat loss. Cooling 155% of the heat gain.
7 more that don't work
- Lennox SL25XPV-024-230ACBA38MV-030-230 indoor · heat 22,200 at 47°F, 25,200 at 17°F, 21,200 at 5°F · cool 22,200Too small to cool
Cooling 74% of your heat gain, outside ENERGY STAR's 90 to 160%.
- Goodman GSZV902410A*CA*F3137*6A* + MBVC1201 indoor · heat 23,000 at 47°F, 16,100 at 17°F, 13,100 at 5°F · cool 23,200Too small to cool
Cooling 77% of your heat gain, outside ENERGY STAR's 90 to 160%.
- Goodman GZV7SA2410A*AHVE36CP1300A* indoor · heat 23,200 at 47°F, 20,900 at 17°F, 17,000 at 5°F · cool 23,200 · ENERGY STAR cold climateToo small to cool
Cooling 77% of your heat gain, outside ENERGY STAR's 90 to 160%.
- Carrier 38MURAQ24AB340MUAAQ24XA3 indoor · heat 24,000 at 47°F, 26,400 at 17°F, 22,600 at 5°F · cool 24,000 · ENERGY STAR cold climateToo small to cool
Cooling 80% of your heat gain, outside ENERGY STAR's 90 to 160%.
- Mitsubishi Electric PUZ-HA24NHAPAA-A24AA1 indoor · heat 25,400 at 47°F, 26,000 at 17°F, 26,000 at 5°F · cool 24,000 · ENERGY STAR cold climateToo small to cool
Cooling 80% of your heat gain, outside ENERGY STAR's 90 to 160%.
- Goodman GSZV906010A*CA*F4961*6D* + MBVC2001 indoor · heat 52,500 at 47°F, 37,400 at 17°F, 29,000 at 5°F · cool 52,500Too big to cool
Cooling 175% of your heat gain, outside ENERGY STAR's 90 to 160%.
- Carrier 38MURAQ60AB340MUAAQ60XA3 indoor · heat 59,000 at 47°F, 52,500 at 17°F, 48,500 at 5°F · cool 55,000 · ENERGY STAR cold climateToo big to cool
Cooling 183% of your heat gain, outside ENERGY STAR's 90 to 160%.
Maximum heating capacity at 5°F outdoors from NEEP's list, November 2026, for the indoor unit shown; a different coil or air handler changes it. Makers list more matches than this.
Heat pumps make less heat as it gets colder. We compare each unit at the rating point at or below your design temperature (47, 17 or 5°F) at maximum speed, so it makes at least that much on a design day. The Manual S should use the maker’s performance data at your exact temperature.
ENERGY STAR keeps a variable-speed heat pump’s cooling capacity at 90 to 130% of the heat gain (up to 160% allowed) in most climates. In a dry, heating-dominated one (ACCA’s Condition B) it allows 90 to 100% plus 15,000 Btu/h. A unit big enough for a cold design day can be too big for summer; that’s when backup heat is the better answer.
Electric strips in the air handler, or a furnace (dual fuel), make up the shortfall. ENERGY STAR recommends controls that use backup heat only when the heat pump fails or can’t meet the load, and cold-climate certified units in climate zones 5 to 8.
How we work it out
capacity at the rating point at or below your design temperature ≥ Manual J heat loss
90% ≤ cooling capacity ÷ Manual J heat gain ≤ 160%
Both loads come from an ACCA Manual J, which the International Residential Code (M1401.3) requires; there's no square-feet rule here. The Manual J guide covers what goes into one.
Heating capacity in the cold
NEEP's Cold Climate Air Source Heat Pump List gives each system's heating capacity at 47, 17 and 5°F outdoors. We take the point at or below your design temperature (17°F for a 20°F design day, 5°F for 10°F) at the unit's maximum speed, so it makes at least that much on a design day. Below 5°F the list stops, and so do we: ask for the maker's extended table. ENERGY STAR's HVAC design report asks for the 17°F and 47°F capacities for the same reason.
Not too big to cool
ENERGY STAR keeps a variable-speed heat pump's cooling capacity at 90 to 130% of the heat gain, with up to 160% allowed (Condition A climates). In dry, heating-dominated places (Condition B) it allows 90 to 100% plus 15,000 Btu/h. If the unit that covers a cold design day is too big for summer, a smaller one plus backup heat is the usual answer.
Backup heat
When a unit falls short at design, the shortfall is what electric strips or a furnace make up: at 3,412 Btu/h per kW (NIST), a 10,000 Btu/h shortfall is about 3 kW. ENERGY STAR recommends controls that hold backup heat for when the heat pump can't keep up, and cold-climate certified units in climate zones 5 to 8.
Design temperature by ZIP
From EPA's ENERGY STAR reference guide (2019 edition): the county's 99% heating design temperature limit, for the county that holds most of your ZIP.
Where the numbers come from
- NEEP: Cold Climate Air Source Heat Pump List
- ENERGY STAR: National HVAC Design Supplement to Std. 310, Rev. 13 (sizing limits)
- ENERGY STAR: Design Temperature Limit Reference Guide (2019 Edition)
- Pima County, AZ: HVAC sizing requirements (quotes IRC M1401.3)
- NIST SP 811: conversion factors (Btu/h to watts)
Heating and cooling
More calculators
- Mini-split sizingWhat size mini-split heats and cools my garage or room?
- BTU to tonsHow many tons is my BTU number, and which mini-split is that?
- AC sizeWhat size AC do I need? What goes into a Manual J, and checking a quote.
- Furnace sizeWhat size furnace do I need for my heat loss and design temperature?
- SEER2 savingsHow much will a higher SEER2 AC or heat pump save?
- AC unit costWhat does a new AC unit, heat pump or furnace cost installed?
- Dehumidifier sizingWhat capacity keeps my garage or basement dry?
- Air filter sizeWhat size furnace or AC filter, which MERV, and how often to change it?